Inductive And Capacitive Proximity Switches

di-soric proximity switches are available in a diverse range of different designs suitable for many applications.

From the standard application to highest technical requirements, di-soric proximity switches perform all tasks perfectly. A complete product program, always utilising the latest technology, providing impressive quality and reliability.

Filter:
Code Operating Principle Size Installation Type Switching Distance Switching Output Connection
KNS D6.5KM 2B G3-T3 Capacitive Ø 6,5 mm Flush 2 mm Push-pull, 100 mA, NO/NC Connector, M8, 3-pin
KNS D6.5KM 2B G3-2R Capacitive Ø 6,5 mm Flush 2 mm Push-pull, 100 mA, NO/NC Cable, 2 m, 3-pin
KNS D6.5KM 3N G3-T3 Capacitive Ø 6,5 mm non-flush 3 mm Push-pull, 100 mA, NO/NC Connector, M8, 3-pin
KNS D6.5KM 3N G3-2R Capacitive Ø 6,5 mm non-flush 3 mm Push-pull, 100 mA, NO/NC Cable, 2 m, 3-pin
KNS M08KM 2B G3-T3 Capacitive M8 x 1 Flush 2 mm Push-pull, 100 mA, NO/NC, switchable via IO-Link Connector, M8, 3-pin
KNS M08KM 2B G3-2R Capacitive M8 x 1 Flush 2 mm Push-pull, 100 mA, NO/NC, switchable via IO-Link Cable, 2 m, M8, 3-pin
KNS M08KM 3N G3-T3 Capacitive M8 x 1 non-flush 3 mm Push-pull, 100 mA, NO/NC, switchable via IO-Link Connector, M8, 3-pin
KNS M08KM 3N G3-2R Capacitive M8 x 1 non-flush 3 mm Push-pull, 100 mA, NO/NC, switchable via IO-Link Cable, 2 m, 3-pin
KNS M12KM 4B G3-B3 Capacitive M12 x 1 Flush 4 mm Push-pull, 100 mA, NO/NC, switchable via IO-Link Connector, M12, 3-pin
KNS M12KM 4B G3-2R Capacitive M12 x 1 Flush 4 mm Push-pull, 100 mA, NO/NC, switchable via IO-Link Cable, 2 m, 3-pin
KNS M12KM 8N G3-B3 Capacitive M12 x 1 non-flush 8 mm Push-pull, 100 mA, NO/NC, switchable via IO-Link Connector, M12, 3-pin
KNS M12KM 8N G3-2R Capacitive M12 x 1 non-flush 8 mm Push-pull, 100 mA, NO/NC, switchable via IO-Link Cable, 2 m, 3-pin
DCBK 08 MN 04 NS-T3 inductive M8 x 1 non-flush 4 mm npn, 200 mA, NO Connector, M8, 3-pin
DCB 12 MB 02 PS-3 inductive M12 x 1 Flush 2 mm pnp, 200 mA, NO Cable, 2 m, 3-pin
DCB 12 MB 02 NS-3 inductive M12 x 1 Flush 2 mm npn, 200 mA, NO Cable, 2 m, 3-pin
DCB 12 MB 02 PS-B3 inductive M12 x 1 Flush 2 mm pnp, 200 mA, NO Connector, M12, 4-pin
DCB 12 MB 02 NS-B3 inductive M12 x 1 Flush 2 mm npn, 200 mA, NO Connector, M12, 4-pin
DCB 12 MN 04 PS-3 inductive M12 x 1 non-flush 4 mm pnp, 200 mA, NO Cable, 2 m, 3-pin
DCB 12 MN 04 NS-3 inductive M12 x 1 non-flush 4 mm npn, 200 mA, NO Cable, 2 m, 3-pin
DCB 12 MN 04 PS-B3 inductive M12 x 1 non-flush 4 mm pnp, 200 mA, NO Connector, M12, 4-pin
DCB 12 MN 04 NS-B3 inductive M12 x 1 non-flush 4 mm npn, 200 mA, NO Connector, M12, 4-pin
DCB 12 MB 04 PS-3 inductive M12 x 1 Flush 4 mm pnp, 200 mA, NO Cable, 2 m, 3-pin
DCB 12 MB 04 NS-3 inductive M12 x 1 Flush 4 mm npn, 200 mA, NO Cable, 2 m, 3-pin
DCB 12 MB 04 PS-B3 inductive M12 x 1 Flush 4 mm pnp, 200 mA, NO Connector, M12, 4-pin